KP 43 Series Tri-Color Display High-Precision Digital Pressure Sensor
Ordering Code

Specification
| Model | KP 43 P ( Positive ) |
KP 43 V ( Negative ) |
KP 43 C ( Even as pressure ) |
|
|---|---|---|---|---|
| Rated pressure range | 0.000 ~ 1.000 MPa | 0.0 ~ -101.3 kPa | -100.0 ~ 100.0 kPa | |
| Set pressure range | -0.100 ~ 1.000 MPa | 10.0 ~ -101.3 kPa | -101.0 ~ 101.0 kPa | |
| Withstanding pressure | 1.5 MPa | 300 kPa | ||
| For gas | Air ,non-corrosive, non-flammable | |||
| Pressure units Set the minimum scale |
kPa | – | 0.1 | |
| MPa | 0.001 | – | ||
| kgf / cm 2 | 0.01 | 0.001 | ||
| bar | 0.01 | 0.001 | ||
| psi | 0.1 | 0.01 | ||
| InHg | – | 0.1 | ||
| mmHg | – | 1 | ||
| Voltage | 12 to 24 V DC ± 10%, ripple peak below 10% | |||
| Current consumption | ≤ 40mA ( No load ) | |||
| Switching output | 2 NPN open collector output 2 PNP open collector output Maximum load current: 125 mA Maximum load current: 125 mA Maximum supply voltage: 30 V DC Maximum supply voltage: 24 V DC Internal voltage drop: 15 V or less Internal voltage drop: 15 V or less |
|||
| Repeatability | ± 0.2% F.S. ± 1 digit or less | |||
| Hysteresis | Single point setting mode | Adjustable [ Note ] * 1 | ||
| Hysteresis mode | ||||
| Window comparator mode | ||||
| Reaction time | ≤ 2.5ms ( Malfunction prevention function: 25 ms, 100 ms, 250 ms, 500 ms, 1000 ms, 1500 ms optional ) |
|||
| Output short circuit protection | Have | |||
| Display | 3 colors ( Red / green / orange ) display ( Sampling rate: 5 times / second ) | |||
| DisplayAccuracy | ± 0.2% FS ± 1 digit ( At ambient temperature: 25 ± 3 ° C ) | |||
| Operation indicator | Orange ( 1 & 2 LED ) OUT 1 / OUT 2 | |||
| Linear analog output ( Voltage output ) [ Note ] * 2 |
Output voltage: 1 ~ 5 V ± (within rated pressure range) 2.5% FS
Linearity: ± 1% F.S. output impedance of about 1 |
|||
| Linear analog output ( Current output ) [ Note ] * 3 |
Output Current: 4 ~ 20 mA ± ( within rated pressure range ) 2.5% FS
Linearity: ± 1% F.S. Maximum load impedance: 300 The minimum load impedance : 50 |
|||
| Resistance to environmental | Protection class | IP 40 | ||
| Ambient temperature | Action: 0 ~ 50 ° C, save: -10 ~ 60 ° C ( Anhydrous gel and without icing conditions ) | |||
| Ambient humidity | Action & Save: 35 ~ 85% RH ( Dry gel ) | |||
| Withstand voltage | 1000 V AC 1 min ( Between lead and plastic shell ) | |||
| Insulation resistance | 50 M ( Between lead and plastic shell ) |
|||
| Vibration resistance | The complex amplitude of 1.5 mm, per 1 minute 10 Hz ~ 55 Hz ~ 10 Hz, X, Y, Z each direction 2 hours | |||
| Impact resistance | 100 m / s 2 ( 10 G ) X 、 Y 、 Z 3 times each direction | |||
| TemperatureCharacteristic | ± 2.5% FS comparative reference temperature 25 ° C ( Within 0 ~ 50 ° C temperature range ) | |||
| Port size | F 1 : R 1 / 8" , M 5 ; F 2 : NPT 1 / 8 " , # 10 ~ 32 UNF ; F 3 : G 1 / 8 " ( BSPP ) , M 5 | |||
| Wire size | Oil-resistant PVC wire ( 0.15 mm 2 ) | |||
| Weight | Approximately 80 g ( Containing 2 meters of wire ) | |||
[ Note ] * 1: Single-point setting mode and window comparator mode adjustable 1 - 8 digits to be poor.
* 2: When selecting voltage output is not current output, two kinds of output patterns can only select one.
* 3: Select the current output is no voltage output, two kinds of output patterns can only select one.
Installation Specification
Pipe types

Mounting bracket

Panel mount

Size Chart / Accessories Type
Dimensions Fig.

Fixation : BT 12

Fixation : BT 13

Panel adapter : PA - C

Panel adapter + front cover : PA - D

Hole size