| Applications |
| Medium |
Liquid; Gaseous medium |
| Medium temperature [ °C ] |
-25 ... 80 |
| Compressive strength [ bar ] |
30 |
| Liquid |
| Medium temperature [ °C ] |
-25 ... 80 |
| Gaseous medium |
| Medium temperature [ °C ] |
-25 ... 80 |
| Electrical data |
| Operating voltage [ V ] |
19 ... 36 DC |
| Current consumption [ mA ] |
< 60 |
| Protection class |
III |
| Reverse protection |
Yes |
| Boot delay time [ s ] |
10 |
| Total input / output |
| Total number of inputs and outputs |
Number of digital outputs: 1 |
| Output |
| Number of outputs |
1 |
| Output signal |
Switch signal |
| Electrical design |
PNP |
| Number of digital outputs |
1 |
| Output function |
Normally open / normally closed; ( parameters can be set ) |
| Maximum switching output DC voltage drop [ V ] |
2.5 |
| Continuous current load of switching output DC [ mA ] |
250 |
| Short circuit protection |
Yes |
| Short circuit protection type |
Pulse |
| Overload protection |
Yes |
| Measurement / setting range |
| Probe length L [ mm ] |
45 |
| Liquid |
| Predetermined area [ cm/s ] |
3 ... 300 |
| Measuring range at maximum sensitivity [ cm/s ] |
3 ... 100 |
| Gaseous medium |
| Predetermined area [ cm/s ] |
200 ... 3000 |
| Measuring range at maximum sensitivity [ cm/s ] |
200 ... 800 |
| Accuracy / deviation |
| Repeatability [ cm/s ] |
1 ... 5 |
| Temperature change rate [ cm/s x 1/K ] |
0.1; ( Applied to water 5...100 cm/s; 10...70 °C ) |
| Maximum temperature gradient of medium [ K/min ] |
300 |
| Switch point accuracy [ cm/s ] |
± 2...± 10; ( Applied to water 5...100 cm/s; 25 °C; factory setting ) |
| Hysteresis [ cm/s ] |
2 ... 5; ( Applied to water 5...100 cm/s; 25 °C; factory setting ) |
| Reaction time |
| Reaction time [ s ] |
1 ... 10 |
| Liquid |
| Reaction time [ s ] |
1 ... 10 |
| Gaseous medium |
| Reaction time [ s ] |
1 ... 10 |
| Software / programming |
| Switch point adjustment |
Button |
| Working conditions |
|
| Ambient temperature [ °C ] |
-25 ... 80 |
| Storage temperature [ °C ] |
-25 ... 100 |
| Enclosure rating |
IP 67 |
| Certification / testing |
| EMC electromagnetic compatibility |
EN 61000-4-2 ESD |
4 kV CD / 8 kV AD |
| EN 61000-4-3RF electromagnetic immunity test |
10 V/m |
| EN 61000-4-4 Burst |
2 kV |
| EN 61000-4-6 High frequency conduction |
10 V |
| Impact resistance |
DIN IEC 68-2-27 |
50 g ( 11 ms ) |
| Seismic |
DIN EN 60068-2-6 |
20 g ( 55...2000 Hz ) |
| MTTF [ year ] |
298 |
| Pressure Equipment Directive |
Good engineering practice; can be applied to group 2 fluids; fluids of group 1 according to demand |
| Mechanical technical data |
| Weight [ g ] |
243.5 |
| Size [ mm ] |
M18 x 1.5 |
| Thread code |
M18 x 1.5 |
| Material |
stainless steel ( 1.4404 / 316L ); stainless steel ( 1.4310/301 ); PC; PBT-GF20; EPDM/X |
| Material ( wet parts ) |
stainless steel ( 1.4404 / 316L ); O-ring: FKM 80 Shore A |
| Process connection |
M18 x 1,5 internal thread |
| Display / operator |
| Display |
Function |
10 x LED, Tricolor |
| Comment |
| Packing unit |
1 piece |
| Electrical connections |
| Connector |
1 x M12 |