| Applications |
| Applications |
Applied in industrial applications |
| Medium |
Compressed air |
| Medium temperature [ °C ] |
0 ... 60 |
| Compressive strength [ bar ] |
16 |
| Electrical data |
| Operating voltage [ V ] |
18 ... 30 DC; ( accord EN 50178 SELV / PELV standard ) |
| Current consumption [ mA ] |
< 110 |
| Protection class |
III |
| Reverse protection |
Yes |
| Boot delay time [ s ] |
1 |
| Total input / output |
| Total number of inputs and outputs |
Number of digital outputs: 2; Number of analog outputs: 1 |
| Output |
| Number of outputs |
2 |
| Output signal |
Switch signal; analog signal; pulse signal; IO-Link; ( configurable ) |
| Electrical design |
PNP |
| Number of digital outputs |
2 |
| Output function |
Normally open / normally closed; ( parameters can be set ) |
| Maximum switching output DC voltage drop [ V ] |
2 |
| Continuous current load of switching output DC [ mA ] |
4...20; ( adjustable range ) |
| Number of analog outputs |
1 |
| Number of analog outputs [ mA ] |
4 ... 20 |
| Maximum load [ Ω ] |
500 |
| Pulse output |
Flowmeter |
| Short circuit protection |
Yes |
| Short circuit protection type |
Pulse |
| Overload protection |
Yes |
| Measurement / setting range |
| Measuring range |
10 ... 1250 l/min |
0.3 ... 103.6 m/s |
0.2 ... 75 m³/h |
| Display range |
0 ... 1500 l/min |
0 ... 124.3 m/s |
0 ... 90 m³/h |
| Switching point, SP |
10 ... 1250 l/min |
0.8 ... 103.6 m/s |
0.6 ... 75 m³/h |
| Restoration point, rP |
4 ... 1244 l/min |
0.3 ... 103.1 m/s |
0.2 ... 74.6 m³/h |
| Starting point of measured value, ASP |
0 .. .938 l/min |
0 ... 77.7 m/s |
0 ... 56.3 m³/h |
| End of measured value, AEP |
312 ... 1250 l/min |
25.9 ... 103.6 m/s |
18.7 ... 75 m³/h |
| Step |
1 l/min |
0.1 m/s |
0.1 m³/h |
| Data monitoring |
| Pulse value |
0.001...1000000 m³ |
| Setting step |
0.001 m³ |
| Pulse length [ s ] |
≥ 0,02 / ≤ 2 |
| Temperature monitoring |
| Measuring range [ °C ] |
0 ... 60 |
| Display range [ °C ] |
-12 ... 72 |
| Accuracy / deviation |
| Data monitoring |
| Repeatability [ % of measured value ] |
± 1,5 |
| Accuracy ( in the measuring range ) |
± (15% MW + 1,5% MEW ); ( applies to the maximum value reached in air quality class 344 ( DIN 8573-1 ); when using pipes with tolerance class T3/T4; the length of the inlet and outlet pipes has no edges and Sudden change in diameter; no burrs on the inner surface of the tube ) |
| Temperature monitoring |
| Accuracy [ K ] |
± 2; ( Medium flow within the limit of flow measurement range ) |
| Reaction time |
| Data monitoring |
| Reaction time [ s ] |
0.1; ( dAP = 0 ) |
| Damping dAP step applied to switch output [ s ] |
0 - 0,2 - 0,4 - 0,6 - 0,8 - 1 |
| Software / programming |
| Parameter setting |
Flow monitoring; quantity meter; preset capacity meter; temperature monitoring; hysteresis/window; normally open/normally closed; current output/pulse output; display screen can be rotated and closed; display unit; totalizer |
| Interface |
|
| Communication Interface |
IO-Link |
| Delivery type |
COM2 ( 38,4 kBaud ) |
| COM2 ( 38,4 k Baud ) |
1.1 |
| SDCI standard |
IEC 61131-9 CDV |
| IO-Link Device ID |
262 d / 00 01 06 h |
| Appearance |
No contour |
| SIO mode |
Yes |
| Required mater port type |
A |
| Analog process data |
3 |
| Two-bit output process data |
2 |
| Minimum processing cycle [ ms ] |
4.1 |
| Working conditions |
|
| Ambient temperature [ °C ] |
0 ... 60 |
| Storage temperature [ °C ] |
-20 ... 85 |
| Maximum allowable relative air humidity [ % ] |
90 |
| Enclosure rating |
IP 65 |
| Certification / testing |
| EMC electromagnetic compatibility |
DIN EN 61000-6-2 |
|
| DIN EN 61000-6-3 |
|
| Seismic |
DIN EN 60068-2-6 |
5 g ( 55 ... 2000 Hz ) |
| MTTF [ year ] |
227 |
| Pressure Equipment Directive |
Good engineering practice; can be applied to group 2 fluids; fluids of group 1 according to demand |
| Mechanical technical data |
| Weight [ g ] |
579 |
| Material |
PBT-GF20; Nitrile rubber; PC; Stainless steel ( 1.4301 / 304 ); PTFE; Brass coating; FKM; Aluminum powder coating |
| Material ( wet parts ) |
Stainless steel (1.4301 / 304); FKM; ceramic glass passivated; PEEK GF30; polyester; aluminum |
| Tightening torque [ Nm ] |
50 |
| Process connection |
Threaded connection G 1/2 DN15 |
| Display / operator |
| Display |
Display unit |
5 x LED, green ( Nl/min, Nm³/h, Nm/s, Nm³, °C ) |
| Function display |
1 x LED, green |
| Switch status |
2 x LED, yellow |
| Measurements |
Alphanumeric display, 4 digits |
| Programming |
Alphanumeric display, 4 digits |
| Comment |
| Comment |
MW = measured value |
| MEW = Final value of the measuring range |
| According to the German industrial standard DIN ISO 2533, the measurement, display and setting range are for standard volumetric flow |
| For instructions on installation and use, please refer to the user guide. |
| Packing unit |
1 piece |
| Electrical connections |
| Connector |
1 x M12 |