Parts And Accessories

SV7504 Flow sensor eddy current

Dimensions

Specifications

Applications
Applications Applied in industrial applications
Medium Water
Medium temperature [ °C ] -10 ... 90
Compressive strength [ bar ] 12
Pay attention to compressive strength Up to 40 °C
Electrical data
Operating voltage [ V ] 18 ... 30 DC
Current consumption [ mA ] < 30
Minimum insulation resistance [ MΩ ] 100; ( 500 V DC )
Protection class III
Reverse protection Yes
Boot delay time [ s ] < 3
Total input / output
Total number of inputs and outputs Number of analog outputs: 2
Output
Number of outputs 2
Output signal Analog signal
Number of digital outputs 2
Number of analog outputs [ mA ] 4 ... 20
Maximum load [ Ω ] 500
Short circuit protection Yes
Overload protection Yes
Measurement / setting range
Measuring range 5 ... 100 l/min 0.3 ... 6 m³/h
Display range 0 ... 120 l/min 0 ... 7.2 m³/h
Resolution 0.5 l/min 0.02 m³/h
Start of measurement, ASP 0...80 l/min 0...4.8 m³/h
End of measured value, AEP 20...100 l/min 1.2...6 m³/h
Measurement dynamics 1:20
Step 0.5 l/min 0.02 m³/h
Temperature monitoring
Measuring range [ °C ] -10 ... 90
Display range [ °C ] -30 ... 110
Resolution [ °C ] 0.5
Start of measurement [ °C ] -10 ... 70
End of measured value [ °C ] 10 ... 90
Set step [ °C ] 0.5
Accuracy / deviation
Data monitoring
Accuracy ( in the measuring range ) ± 2 % MEW
Repeatability ± 0,5 % MEW
Temperature monitoring
Accuracy [ K ] ± 1
Reaction time
Data monitoring
Reaction time [ s ] 1; ( dAP = 0 )
Damping applied to switch output dAP [ s ] 0 ... 5
Temperature monitoring
Response time T05 / T09 [ s ] T09 = 6
Software / programming
Parameter setting Damping applied to analog output (dAA); display unit
Working conditions  
Ambient temperature [ °C ] 0 ... 60
Pay attention to the ambient temperature Medium temperature < 80 °C
Medium temperature < 90 °C: 0 ... 50 °C
Storage temperature [ °C ] -20 ... 80
Enclosure rating IP 65; IP 67
Certification / testing
EMC electromagnetic compatibility DIN EN 61000-6-2  
DIN EN 61000-6-3  
Impact resistance DIN EN 60068-2-27 5 g ( 11 ms )
Seismic DIN EN 60068-2-6 With water / 10 ... 50 Hz 1 mm
  With water / 50 ... 2000 Hz 2 g
MTTF [ year ] 342
UL certification UL certification number I002
Pressure Equipment Directive Good engineering practice; can be applied to group 2 fluids; fluids of group 1 according to demand
Mechanical technical data
Weight [ g ] 486.5
Material stainless steel ( 1.4404 / 316L ); PC; PBT+PC-GF30; PPS; TPE-U
Material ( wet parts ) stainless steel ( 1.4404 / 316L ); ETFE; PA 6T; PPS; FKM
Tightening torque [ Nm ] 30
Process connection Threaded connection Rc 3/4 internal thread DN20
Comment
Comment MW = Measurements
MEW = Final value of the measuring range
Packing unit 1 piece
Electrical connections
Connector Connector: 1 x M12; contacts Contact: gold-plated

Online Inquiry